In this guide, we will show how to replace the Toolhead Board on the A1 mini.
If you prefer a Video Guide, it is available in the lower section of this wiki article.
This guide is intended for use if there is a problem with the Toolhead board.
Common issues that may indicate the need for replacement of the A1 mini Toolhead Board include:
Bambu Lab Toolhead Board for A1 mini
IMPORTANT!
It's crucial to power off the printer before conducting any maintenance work, including work on the printer's electronics and tool head wires. Performing tasks with the printer on can result in a short circuit, leading to electronic damage and safety hazards.
During maintenance or troubleshooting, you may need to disassemble parts, including the hotend. This exposes wires and electrical components that could short circuit if they contact each other, other metal, or electronic components while the printer is still on. This can result in damage to the printer's electronics and additional issues.
Therefore, it's crucial to turn off the printer and disconnect it from the power source before conducting any maintenance. This prevents short circuits or damage to the printer's electronics, ensuring safe and effective maintenance. For any concerns or questions about following this guide, open a new ticket in our Support Page and we will do our best to respond promptly and provide the assistance you need.
The first step in replacing the faulty Toolhead Board is to remove the back cover of the print head.
Carefully pry open the back cover by pulling on the bottom section as shown below.
Next, remove the four screws holding the USB C cable secure on the tool head of the A1 mini.
After removing the screws, the USB C cable can be pulled upwards to remove it.
Remove the three black screws holding the Toolhead Board in place.
Next, remove the four cables attached to the Toolhead Board.
Carefully pull them out by the connector, and avoid pulling the wires from the connectors.
We recommend using a flat tool to gently pry them out to avoid any potential damage.
Don't forget to also remove the Eddy sensor wires which are held in place by two screws.
You can now remove the Tollhead Board from the plastic housing.
Be careful when pulling it out, as you will need to carefully disconnect the filament sensor ribbon cable.
Pull it slowly and straight upwards. Avoid wiggling the ribbon cable as it can cause damage to it. If you have damaged it, you can order a replacement from this link
The first step in installing the new Tollhead Board is to attach it back on the printhead housing.
Start by re-connecting the filament sensor ribbon cable on top of the board. Gently push the ribbon cable in the connector.
Carefully route the Extruder Motor cable next to the ribbon cable as shown in the image below.
After this step is done, you can gently push the Toolhead Board back in its position.
Use the three black screws to re-attach the Toolhead Board back to the print head.
Important!
Do not overtighten the screws to avoid any potential damage
With the new Toolhead Board back in its original position, you can re-connect all the wires as shown below.
Re-install the USB cable using the four screws we removed in the first step, while being careful about the orientation.
Important!
Do not over-tighten these screws, as the threads can damage the plastic.
Take note of the USB cable orientation and the small groove from the back that aligns it.
The USB C cable only fits in one position, with the correct orientation having the line in the cable connector aligned to the back of the printer and tool head.
Finally, install the back cover of the A1 mini print head.
The back cover clips in place. Simply align the two brackets on the back cover towards the top, then push it until you hear a few clicks.
We recommend conducting a full calibration of the printer after this operation.
Additionally, it's strongly advised to wash the PEI textured plate before use, as it may have been contaminated during this process.
If you encounter problems during the installation of a new Toolhead Board, please check the potential problems and solutions listed below:
Check the Hotend Heating Assembly connector and confirm it is correctly inserted, as shown in Step 3. Re-connect all the cables
It is important to carefully align the connector pins to the Toolhead Board.
If the issue persists, the thermistor wires might have been damaged (White wires)
Check the Hotend Heating Assembly connector and confirm it is correctly inserted, as shown in Step 3. Re-connect all the cables
It is important to carefully align the connector pins to the Toolhead Board.
If the issue persists, the heater wires might have been damaged (Translucent wires)
Check the Eddy Sensor wires (5 and 6) and confirm they are correctly installed on the back of the Toolhead Board, as shown in Step 3. Re-connect all the cables
Check the Ribbon Cable and confirm it is correctly installed on the back of the Toolhead Board, as shown in Step 1. Attach the Toolhead Board to the housing
If the ribbon cable is damaged, you will need to replace the Filament Sensor.
We hope the detailed guide provided has been helpful and informative.
To ensure a safe and effective execution, if you have any concerns or questions about the process described in this article, we recommend reaching out to technical support team before initiating the operation. We will do our best to respond promptly and provide the assistance you need. Click here to open a new ticket in our Support Page.