The Bambu Lab X1/P1 series printers come with the hotbed correctly trammed from the factory. Due to various shipping conditions, the bed trimming can be inaccurate.
To help solve this problem, we prepared a Bed Tramming Procedure to ensure the printing surface is perfectly leveled.
The bed leveling procedure should be done only if you notice an inaccuracy in the bed leveling, or if asked by the customer service team.
Putting or not putting the plate is allowed during the procedure.
Before starting the bed leveling procedure, it's important to prepare the printer:
Please note that the tension shown in the image below is used as a reference to start with the same amount of tension on each knob, when doing the leveling procedure.
It serves as a baseline and needs to be used with the included g-code below for the bed leveling procedure to be correctly done.
If you set the correct tension shown in the picture from the middle, it does not mean that your heatbed is correctly trammed, and you still need to go through the leveling process below.
To begin the bed leveling process, first, download the attached g-code file, and transfer it to a MicroSD Card.
/x1/manual/bed-leveling/hotbed_tramming.gcode
Insert the MicroSD card, and “print” the g-code file.
After the g-code file was loaded, the printer will home, then move over to the front left corner and wait for 30 seconds. When this happens, carefully turn the corresponding bed leveling knob until the printing surface barely touches the nozzle.
Please make sure that the nozzle is just touching the printing surface. The nozzle should not push against the printing surface, and there should be no gap between the nozzle and the bed.
After 30 seconds, the nozzle will move over the back bed leveling knob. Repeat the procedure until the nozzle barely touches the bed. The same will happen on the front right bed leveling knob.
When the first leveling is done, the process will be repeated two more times, this time with 15-second pauses, to allow you to fine-tune the adjustment and double-check the distance between the nozzle and the bed.
If at any point the bed leveling procedure needs to be repeated, ensure that all the steps are followed from the beginning of the guide.
The bed leveling knobs need to be tightened again, as instructed, before using the g-code file provided.
We hope the detailed guide provided has been helpful and informative.
To ensure a safe and effective execution, if you have any concerns or questions about the process described in this article, we recommend submitting a Technical ticket regarding your issue. Please include a picture or video illustrating the problem, as well as any additional information related to your inquiry.